Case study
Regeneration of drawing oil for high-voltage cables
Automatic centrifuge connected to 3 drawing lines
Energy

From need to implementation
Each drawing line is equipped with a lifting pump that transfers part of the oil to the centrifuge tank. The regeneration cycle can then be carried out in masked time before returning to the drawing machine tank. The centrifuge operates automatically. The extracted sludge is automatically transferred to a hopper located under the drawing machine. No manual intervention is required to empty the sludge. This system guarantees continuous, uninterrupted operation, while reducing maintenance requirements.

90 l/min flow rate
The viscosity of this oil was very high. There was no chance of using conventional filtration solutions, so the centrifuge made sense for this application.
Stéphane Demin, Manager of Filtres Monnet
Experts at your service
Need filtration? Contact us